R1 Heat Treasure Robot

HotBot replaces manual physiotherapy treatments with robotic arms, offering lightweight manual control, precise positioning, intelligent temperature and intensity regulation, and automated massage path planning. It seamlessly integrates traditional physiotherapy with cutting-edge smart technology solutions, leveraging big data, AI vision algorithms, and IoT to effectively address modern sub-health issues and enhance key physiological functions such as immune system support.




product details

Precautions

  • Before operation, carefully read the instruction manual to familiarize yourself with all safety requirements, operating procedures, and maintenance instructions. This instrument and its accessories must not be used unless the instruction manual has been followed. Furthermore, this instrument must not be used for any purpose other than its intended application.
  • Warning: Do not modify this instrument without prior notification from the manufacturer.
  • Before connecting the instrument to the power supply for the first time, be sure to verify that the power supply parameters comply with the requirements specified in the user manual. The power supply to which the instrument is connected must be installed and modified in accordance with the electrical installation standards applicable to the installation location.
  • This instrument must be transported, stored, and operated only in the environments specified in the user manual. It is intended for indoor use only. Do not use this instrument in environments where there is a risk of explosion or water ingress, or in dusty or humid conditions.
  • To avoid unnecessary interference, do not expose this instrument to direct sunlight and keep it away from strong electrostatic and electromagnetic fields (such as diathermy equipment, X-ray machines, mobile phones, and other RF devices). If unexpected interference occurs, move the instrument away from the source of interference or contact an SOG-authorized after-sales service center.
  • The instrument generates heat during operation; therefore, do not place it near heat-producing equipment. Ventilation openings are provided on the rear and bottom panels—do not block them. When positioning the instrument, maintain a minimum clearance of 10 cm between the rear panel and the wall.
  • Do not place any heat-generating, water-containing, or liquid-filled items on the instrument.
  • When moving the instrument from a low-temperature environment to a warm one, wait at least 2 hours to allow the temperature to stabilize before powering on.
  • Do not open or move the protective enclosure, nor disassemble this instrument; otherwise, electric shock may occur, resulting in serious personal injury. After-sales service for this instrument must be performed by SOG-authorized service personnel; otherwise, SOG shall bear no responsibility whatsoever for any subsequent operations on the instrument.
  • Do not insert the accessory connector or any other connectors into the original instrument, as this may result in electric shock and severe damage to the instrument.
  • Before each use, carefully inspect the instrument and its accessories for mechanical damage, functional malfunctions, or other defects. If any malfunction or abnormal condition is detected, immediately cease use and contact SOG’s authorized after-sales service department. Any damage resulting from the use of the instrument or its accessories under non-standard conditions shall be the sole responsibility of the user.
  • Before starting the operation, please verify that all input parameters match the user’s expected settings.

 

Product Introduction

Product Performance Features

HotBot is a cutting-edge, professional health therapy device that delivers selective thermal treatment to targeted tissues using high-frequency electromagnetic energy.
HotBot replaces manual physiotherapy with robotic arms, offering lightweight manual control, precise positioning, intelligent temperature and intensity regulation, and automated massage path planning. It seamlessly integrates traditional physiotherapy with smart technology solutions, leveraging big data, AI vision algorithms, and IoT to effectively address modern sub-health issues and enhance key physiological functions such as immune system support.


Product Advantages

  • Greater Flexibility: Robotic arms replace human hands, enabling more sophisticated and stable operations.
  • Even more reassuring: it employs multiple safety protection mechanisms to achieve precise temperature and intensity control.
  • Greater precision: AI algorithms enable precise localization and automated path planning, lowering the operational threshold.
  • More private: Ensures greater privacy for the service and includes music therapy features.
  • More efficient: delivers stable energy output and reduces labor costs by more than fivefold.
  • More efficient: offering comprehensive, professional care plans and equipped with evidence-based, intelligent clinical pathways.

 

Introduction to Instrument Components

Host

Patch connection cable

Patch

Power cord

Remote control

 

 

An instrument manipulator

B Instrument Handle

Westvent

D-wheel lock

E display

F switch button

G Remote Control

H round

 

Preparation Before Use

Hardware Operation Overview

Wheel lock: As shown in the diagram, slide it upward to unlock and press it downward to lock.

When connecting the HotBot to power, set the switch to the “I” position to turn it on, and to the “O” position to turn it off.

As shown in the figure, the circular button on the display is the power button. After connecting the power, press and hold this power button for 2 seconds to turn on the device.  
The red button on the front panel of the instrument is the emergency stop button. In an emergency, press this button to immediately halt the instrument’s operation. To restart the instrument, rotate the button clockwise; otherwise, the instrument will not power on.

The remote control shown in the above figure allows users to adjust the intensity, energy level, and call service according to their preferences.  
 

 

The figure above shows the patch-connecting cable. Before beginning therapy, connect the cable’s circular connector to the port on the right side of the instrument console; the clamp at the other end is used to securely affix the negative electrode patch to the patient’s skin.

The silver metal component shown in the figure is the physiotherapy probe, which can be removed for cleaning after treatment. The protective cover above the probe is designed to prevent gel from entering and can also be removed for cleaning after treatment.

 

Position the HotBot locator parallel to the machine bed and adjust it to the appropriate working position.

Note: It is recommended that the bed height be at least 60 cm, with an additional 5 cm.

The optimal distance for physiotherapy is 45 ± 2 centimeters to the right of the body’s midline.

 

How to use

The above figure shows the home page displayed after completing the self-assessment.
To upgrade the app, please tap the button shown to go to the settings page.

Tap “Network Settings,” select an available Wi-Fi network, and enter the password to complete the initial connection. After that, the device will connect to the network automatically. To switch networks, simply tap the desired network to connect. If the network password has changed, tap “Do Not Save” to clear the saved password, then re-enter the new password to reconnect.

The screenshot above shows the interface for the first network connection. You need to enter the password and tap “Join.” The system will automatically save the details of the connected network, allowing you to reconnect quickly next time.

After connecting to the network, click “Version Upgrade” → “Check for Update.” If a new version is available, a version upgrade prompt will appear. Click “OK” to proceed.

Note: If the network connection is poor, clicking the “OK” button may be delayed. Please wait a moment.

Enter the “Pose Adjustment” page. “Long-press to return to the packing position” retracts the robotic arm into the packed configuration for easier transportation; “Long-press to return to the home position” restores the system to its standby operating state; and “Long-press to enter the cleaning position” raises the therapy probe, facilitating the removal and cleaning of the probe and its protective cover.

Pairing the remote control: Tap “Remote Pairing” → “Start” → Press any button on the remote (a prompt will appear upon detection) → Tap “Finish.” Once the setup is complete, tap the “Back” button in the top-left corner to return to the home screen.

HotBot is available in two versions: a standalone version and a web-based version, each with a different login method. The standalone version can be accessed directly, while the web version requires logging in by scanning a barcode. After completing the general settings, the standalone version can be launched directly from the home page as shown above; for the web version, please refer to the instructions in the image on the right.

The online version requires you to scan the QR code above and use the SOGIOT mobile app. To download the SOGIOT mobile app: Android users can download, install, and register for “SOGIOT” through app stores such as Yingyongbao and the Huawei AppGallery; Apple users can download, install, and register for the app via the App Store.

Log in to the SOGIOT application
Go to the Customer Menu page and click the “+” icon in the upper-right corner to create a customer.

Edit user information and confirm
Select “R1” as the device type, then click the “Scan” button in the upper-right corner. Scan the QR code on the HotBot homepage, followed by the QR code on the consumables. Once the scans are successful, click “Retrieve Information” to log in to the instrument.

Click to select a package and go to the package selection page.

Select the appropriate treatment package based on the client’s symptoms and needs.

Apply the patch to the patient according to the instructions, evenly spreading a layer of gel over the treatment area, then click “Ready” to enter the positioning interface.

Click “Ready” to enter the “Calibrate Treatment Area” interface. First, use the left-side control buttons to position the robotic arm directly above the treatment area; then make fine adjustments to the virtual image until it is perfectly aligned with the treatment area on the patient’s body; finally, click “Complete Positioning.”
 

The figure above shows the interface during the physiotherapy session. During treatment, you can pause, stop, and adjust the volume and energy level.

During treatment, you can tap the “Parameter Settings” button in the upper-right corner to adjust settings such as energy, speed, intensity, alert sound, music playback, moonlight mode, and infrared light. Once you’ve made your adjustments, simply tap “Confirm” to apply the changes immediately.

After the treatment course is completed, the robotic arm will automatically retract. If you need to end the treatment early, please first click “End Treatment” and then click “Confirm.”

Once treatment is confirmed to be complete, the system will redirect to the screen shown above and display a message indicating that treatment has ended. Please click “Complete” to proceed.

After the treatment is completed, you will be reminded to clean the therapy probe promptly. Please remove the adhesive patch and protective cover, then rinse thoroughly with clean water.

Click to enter the “Pose Adjustment” page, then tap “Long Press to Return to Packaging Position,” and fully retract the robotic arm before releasing. Next, return to the home screen, tap the “Power Off” button at the bottom to shut down the device, and unplug the power cord. Finally, pack the power cable, remote control, and instrument together with the cushioning foam back into the original shipping box, restoring the equipment to its original packaged condition.

Caution: The device is shipped in its packaging. Upon power-up, the robotic arm will automatically return to its initial treatment position. Do not place the device near a wall to prevent collisions.

Tap the “Settings” button at the bottom of the homepage to access the settings page.

 

Basic Parameters

Category Details
Operating Environment

Conditions of Use: For Indoor Use

Atmospheric pressure: 700–1060 hPa

Ambient temperature: 0°C to +40°C

Position: Flat

Electric shock protection type: Class I

Relative humidity: 15%–80%

Power Supply Requirements

Operating voltage: 100–240 VAC

Power switch: Located on the rear panel of the instrument. Set to “O” to turn off; set to “I” to turn on. If the instrument will not be used for an extended period, please set the switch to “O”.

Storage Conditions

Ambient temperature: 0°C to +40°C

Relative humidity: 15%–80%

Other conditions: Transportation only in the original packaging.

Product Specifications

Robot working radius: 922 mm

Product dimensions: 490* 860* 1120mm

Output power: 400 VA

Robot arm payload: 5 kg

Instrument weight: 115 kg

 

Maintenance and Care

Daily Maintenance

Timely cleaning of the product helps safeguard customer health and extend the instrument’s service life. Be sure to clean the instrument after each day’s use.

  • Remove the patch and protective cover, then rinse with clean water.
  • Use a brush to thoroughly clean the gel from the patch’s recessed grooves.
  • Before reassembling the protective cover and patch onto the therapy probe, please wipe them clean with a paper towel.

Note: It is recommended to clean the therapy probe after each use.

 

Common Faults and Troubleshooting

Serial Number Fault Solution
1 Robotic arm operation anomaly In this situation, press the “Emergency Stop” button to halt the instrument. Once the test is passed, release the “Emergency Stop” button to restart it.
2 During physical therapy, the skin may feel excessively warm or experience a stinging sensation. This is usually caused by setting the energy level too high. Please reduce the energy level, or ensure that gel is applied correctly and generously to the treatment area.
3 During physiotherapy, there is no sensation of warmth on the skin or no energy output. Check whether the negative cable connection is normal, or whether the patch connection is normal.
4 The system indicates excessive pressure, and the robotic arm retracts to its initial position. This situation typically occurs during treatment when the client applies excessive force while pressing the physiotherapy probe. Please check whether too much pressure has been applied; if so, the handpiece will automatically retract to its initial position. Simply click “Continue” to resume treatment.
5 The system prompts that the probe has been paused, and the robotic arm has retracted to its home position. This is usually caused by the patient moving or being improperly positioned during treatment, resulting in the physiotherapy probe losing contact with the body. You can click “Continue” to resume treatment.
6 The system has detected a sensor fault, and the robotic arm has retracted to its home position. Check the sensor lens for any foreign objects and clean it thoroughly. Click “Continue” to see if the issue has been resolved. If the problem persists, please contact technical support for assistance.
7 Abnormal robotic arm posture during treatment. This may be due to clothing or towels around the treatment area being too exposed, which can interfere with the sensor’s readings. Please smooth out the clothing or towel before continuing the treatment.

 

Warranty

The warranty period for this product may vary depending on the country or region of sale. To the extent permitted by local law, we will extend the warranty wherever possible. From the date of purchase, any failures caused by manufacturing defects are covered under Cilin’s warranty and are entitled to one year of warranty service.

 

Disclaimer

  • This user manual does not provide a comprehensive guide to all aspects of instrument operation. Cilin shall bear no liability for any direct adverse consequences or side effects resulting from the operation of the instrument by untrained personnel.
  • Operators must undergo training at an authorized sales outlet before using this instrument.
  • This instrument shall be periodically calibrated and maintained by Cilin-approved qualified personnel to ensure its proper operation; all associated costs shall be borne by the customer.

Special Statement

  • Cilin does not provide warranty, return, or replacement services under the following circumstances:
  • Unauthorized personnel perform installation or maintenance on the instrument.
  • Use stock solutions that have not been approved by Cilin.
  • Using electrical equipment at the installation site that does not comply with IEC and UL requirements.
  • The instrument was not operated in accordance with the instructions in the user manual.

In view of our commitment to the quality and innovation of this product, we reserve the right to discontinue or modify the specifications, price, design, functions, model, or equipment of this instrument at any time, without incurring any liability in connection therewith.